Power Keeps Tripping? MCB vs RCCB and How to Find the Cause

By SG QuickFixLast updated 7 min read

Quick answer

When power keeps tripping in a Singapore home, a DB box switch is cutting off a fault: an MCB trips on overload or short circuit, the RCCB on earth leakage. With dry hands, switch all MCBs off, reset, then turn them on one by one and leave off the one that trips. SG QuickFix diagnoses power trips from $80.

SG QuickFix pricesTap to WhatsApp

Power trip diagnosisFrom $80
Appliance-related trip diagnosisFrom $80
Circuit fault tracingFrom $100
Complex concealed wiring faultQuote after diagnosis

Current SG QuickFix starting prices. Final price confirmed before work begins.

Not sure? WhatsApp us a photo or 10-second video and we'll tell you if it's a DIY fix.

WhatsApp us
Open DB box on the wall near the main door of an HDB flat, with one breaker lever down after a power trip

Why does the power in my home keep tripping?

A tripped switch in your DB box is cutting off a fault: an overload, a short circuit or current leaking to earth.

According to HDB, an MCB (miniature circuit breaker) trips "in the event of overcurrent due to an overload or short-circuit", and each single-pole MCB protects one circuit. The RCCB (residual current circuit breaker) cuts off electricity in your flat when it detects earth current leakage (HDB: Electrical accessories and wiring). Leakage is current escaping to earth, which can give someone a shock.

A repeat trip usually means the fault is still there: isolate one circuit, then one appliance. If that doesn't pin it down, power trip diagnosis traces it circuit by circuit.

Which switch tripped in the DB box?

Look for the lever that is down or halfway: it shows whether one circuit, leakage or the whole flat's load is the problem.

What each tripped switch means
Switch that is downHow to recognise itWhat it usually means
One single-pole MCBNarrow switch; only part of the flat is offOverload or short circuit on that circuit
RCCBWider switch with a "T" test button; usually the whole flat goes darkEarth leakage on a circuit it protects
Main double-pole MCBWider switch with no test buttonThe flat drew more than its rating, or a serious fault
Nothing is downCorridor lights or neighbours are out tooA supply fault outside your flat

Note which lever dropped first; resale flats often lack labels. In some older flats not every circuit runs through the RCCB, and some newer boards use RCBOs, which do both jobs on one circuit.

If nothing is down and your neighbours are dark too, report it to SP Group's 24-hour supply line on 1800 778 8888 (SP Group: 24-hour hotline). See who to call for an HDB power trip.

HDB DB box with the door open, a row of MCB switches up and the RCCB lever down in the tripped position

What causes power trips in HDB flats?

Most repeat trips trace to one appliance, one damp fitting or one overloaded circuit. When it trips tells you which.

Trip pattern, likely cause and first step
When it tripsSwitchLikely causeSafe first step
As soon as you reset itMCB or RCCBA short circuit or earth fault still presentUnplug everything on that circuit, retry once, then stop
After minutes with the kettle, microwave and air fryer onOne MCBKitchen circuit overloadRun heavy appliances one at a time
When one appliance starts or heats upRCCBLeakage in that applianceUnplug it and see if the trips stop
With nothing plugged inMCB or RCCBFixed wiring, or a hard-wired water heater, aircon, light or fanSwitch off the heater and aircon isolators, then retest once
During or after rainRCCBWater in an outdoor or yard socket, light, aircon outdoor unit or cableLeave that circuit off until checked
At nightUsually RCCBAircon fault, a fridge's defrost heater, or dampNote what was running

EMA and HDB say leakages are "caused by ageing or exposed wires, faulty electrical appliances, and damaged insulation" (HDB: RCCBs required in all homes). In most HDB flats the usual suspects are the water heater element, the washing machine, an old fridge, yard sockets after rain, and ceiling lights below a leak from upstairs. HDB puts PVC cable life at about 25 years, so original wiring in older flats is more prone to faults.

Separate guides cover a water heater that keeps tripping, an oven or kettle that trips the power, and why power trips at night.

How do I find the faulty circuit or appliance safely?

Switch every single-pole MCB off, reset the RCCB or main switch, then switch the MCBs back on one at a time.

  1. Unplug heavy appliances such as the kettle, oven and washing machine.
  2. Switch all single-pole MCBs to off.
  3. Push the RCCB, or the main switch, back up.
  4. Switch the MCBs on one at a time, a few seconds apart.
  5. When a switch trips, the circuit you just switched on is the faulty one. Switch its MCB off.
  6. Unplug everything on that circuit, switch its MCB on, then plug appliances in one at a time.
  7. If it trips with nothing plugged in, or when one appliance goes in, leave that circuit off or that appliance unplugged until checked.

If the RCCB won't stay up even with every MCB off, the fault is in the RCCB, the wiring before it, or a neutral fault a single-pole MCB can't cut off. Stop there.

Mistakes that make things worse:

  • Resetting again and again while the fault is still there.
  • Taping or holding the lever up.
  • Fitting a higher-rated MCB so it stops tripping: it no longer protects the cable.
  • Running a water heater off an extension cord: the Consumer Product Safety Office says it needs a double-pole switch wired by a licensed electrical worker (CPSO: Water heater safety).
Hand switching single-pole MCBs back on one at a time in an HDB DB box to find the circuit that trips

Could the RCCB itself be faulty?

Sometimes. An RCCB that doesn't switch off when you press its "T" button may be defective, and HDB says to have a licensed electrician replace it.

HDB advises testing the RCCB monthly: switch off computers, press "T", and the power should cut; then push the lever back up. Since 1 Jul 2023, EMA requires 30 mA RCCB protection on a home's socket and lighting circuits (EMA Circular RD/E01/2023); the device is marked "0,03A".

An RCCB usually trips between half and all of that rating, so small leaks from many appliances can add up with no single faulty item. An ageing RCCB can also nuisance-trip or, worse, fail to trip; the monthly test checks this. If an electrician finds every circuit healthy but it still trips, the RCCB is the likely suspect; see RCCB tripping but not the MCB.

Replacing it isn't DIY. The Ministry of Trade and Industry (MTI) states that all electrical works, including installing wiring and RCCBs, must be done by a licensed electrical worker (MTI: Electrical Installations Regulations reply). Have a faulty one replaced rather than bypassing it; see circuit breaker and DB services.

How much does it cost to fix a power trip in Singapore?

SG QuickFix diagnoses power trips from $80. Repairs and parts are priced separately.

Power trip jobs and prices
JobWhen you need itSG QuickFix price
Power trip diagnosisTrips keep coming back and you can't find the causeFrom $80
Appliance-related trip diagnosisThe trip follows one applianceFrom $80
Circuit fault tracingIt trips with nothing plugged in, or straight after resetFrom $100
Complex concealed wiring faultA damp, drilled or damaged cable inside a wall or ceilingQuote after diagnosis
MCB replacementAn MCB trips under normal load or won't stay upFrom $120
RCCB / RCD replacementThe RCCB fails its test, or trips after the circuits test healthyFrom $180

Concealed or false-ceiling wiring and DB rectification raise the price. For an accurate price, send a photo of the DB box showing which lever is down and note what was running. See the full electrician price list for Singapore.

DIY or call a professional
Safe to DIY if…Call a professional if…
One MCB tripped once and stays up with fewer appliances runningIt trips again straight after reset, or keeps coming back
The trips stop when one appliance is unpluggedIt trips with nothing plugged in: licensed electrical worker
You are pressing "T" to test the RCCB monthlyThe RCCB fails its test or won't stay up with every MCB off
Don't swap a breaker, remove the DB box's inner cover or rewire anything yourselfYou smell burning or see scorch marks, heat or water near the DB box

What happens when you WhatsApp us?

  1. 1WhatsApp us a photo or short video of the problem.
  2. 2We confirm the price before we come.
  3. 3A technician arrives at the agreed time.
  4. 4The job is done and you pay only the confirmed price.

Electrical Troubleshooting / Power Trip

From $80

  • Fault finding
  • Short-circuit repair

Electrical Troubleshooting / Power Trip FAQs

Related services

Serving Bedok, Pasir Ris, Punggol, Sengkang and Tampines and island-wide.

Sources & updates
  • Updated 1 Oct 2026: First published
Share:

Related guides

Still need help with electrical troubleshooting / power trip?

WhatsApp us a photo and get a clear price before we come. Open 24 hours, island-wide.

WhatsApp us

This guide is general information for homes in Singapore. It is not professional, legal or safety advice for your specific situation. Electrical, gas and some plumbing work can be dangerous, and Singapore law requires certain jobs to be done by licensed workers. Any work you carry out yourself is at your own risk, and SG QuickFix accepts no responsibility for any loss, damage or injury arising from the use of this information. Prices shown are current starting prices, may change, and the final price is confirmed before any work begins. Rules and figures from HDB, PUB, EMA, SP Group and town councils were correct when last checked; please confirm with the relevant authority before acting.

We use cookies to improve your experience and measure traffic. See our Privacy Policy.